Solution
There could be several causes for this error including:
- NI Service crashes.
- Unexpected PC shutdown or crashes.
- Software or registry corruptions.
- Conflicts with 3rd party software or drivers.
Follow the steps below to resolve this error:
- Make sure the NIMAX.exe has fully closed.
1. Open Windows Task Manager.
- On Windows 7, click the Processes tab and select NIMAX.exe.
- On Windows 10 & 11, click on Measurement & Automation Explorer.
- For older versions of NI MAX, click on nimxs.exe.
2. Click End Process or End task and click Yes.
- Restart or start NI Configuration Manager and NI Device Loader services.
- Reboot the computer to restart the services.
- If you want to restart the services manually, go to Control Panel » Administrative Tools » Services.
- Right-click the line NI Configuration Manager and select Start or Restart.
- Repeat the previous step with the NI Device Loader service.
- Close the Services application and restart MAX for the changes to take effect. MAX should now operate correctly.
Note: Another option is to right-click on each service and select Properties. You can check to see if the service is running in the Service status section. If it is not running, click Start.
- Modify the NI Configuration Manager and NI Device Loader recovery settings to help avoid the problem in the future.
- Navigate to their Recovery tabs in the Properties window and select Restart the Service from the First failure, Second failure, and Subsequent failures list boxes, as shown in the image below.
- Reset the MAX database.
- If you did not use NI Package Manager to install your software: Force reinstall your software.
- If you did use NI Package Manager to install your software: Repair your driver from NI Package Manager.
- Download the latest version of your driver, or System Configuration , that is compatible with you hardware and system. This will create a new database file.
- Perform a Clean Boot to determine whether 3rd party drivers or software are conflicting with NI MAX.
- Use the System File Checker to identify corrupt registries or missing files.