Run-Time Error -1074134944 Occurs When Executing the Sequence

Updated Aug 28, 2024

Reported In

Hardware

  • PXI-6552

Software

  • TestStand

Issue Details

When executing the sequence with the LabVIEW code module the Run-Time Error -1074134944 occurs. The VI functions properly on its own and can communicate with the PXI-6552 module without issues.

image.png

Solution

The issue might be due to a device naming conflict in our drivers. Renaming the device in NI MAX can help synchronize the drivers and resolve the conflict.

If after device renaming the problem persists, try resetting the configuration data in NI MAX:

  • In NI MAX, go to Tools » Reset Configuration Data.
  • Ensure you save any unsaved work in open programs. When prompted with a dialog box, select Yes to restart your computer