Issue Details

When I develop source code on ECUTS, I find I  don't know the pin definitions of VPC(Virginia Panel Corporation) 9025 Receiver modules. In this article, I will introduce how to retrive the pin definitions.
 

Solution

When a new ECUTS arrived at customer site, there are several existed folders to store ECUTS related documents including: User Manual, Specifications, ECU Test System Configuration-Specific Reference.html, Test System Maintenance Software Help. We will focus on the Configuration Specific documentation in this article. Steps are as below:
1. Navigate to  C:\Users\Public\Documents\National Instruments\ECU Test System\Configuration Specific Documentation\ 
2. Open ECU Test System Configuration-Specific Reference.html and navigate to Mass Interconnect Overview section.
 
      Mass Interconnect Overview  Click on a slot or module in the following image to navigate to detailed information about that slot/module.  14 1 5  22  24  25  A O  A D  A O  0 C  囗 囗 囗 囗  囗 囗 囗 囗  O 囗 囗  O 囗 囗  囗 囗 囗 囗  O 囗 囗  囗 囗 囗 囗  ㄖ ㄖ  囗 囗 囗 囗  囗 囗 囗 囗  囗 囗 囗 囗  囗 囗 囗 囗  囗 囗 囗 囗  囗 囗 囗 囗  O 口  囗 囗 囗 囗  囗 囗 囗 囗  0 0 0 0 0 0  囗 囗 囗 囗  囗 囗 囗 囗  囗 囗 囗 囗  囗 囗 囗 囗
3. Click on a slot. For example, Slot J24. It will navigate to the pin definitions of the slot. And we can get the pin definitions as below picture.
 
      Slot J24  J24 Pinout  J24  J24  p ps  p ps  2  3  4  5  6  7  8  9  10  11  12  13  14  15  16  1 OUT  Reserved  Reserved  Reserved  Reserved  Reserved  Reserved  Reserved  Reserved  Reserved  Reserved  Reserved  Reserved  Reserved  Reserved  J24 PPS 1 SENSE+  J24 PPS 1 SENSE-  Reserved  Reserved  Reserved  Reserved  Reserved  Reserved  Reserved  Reserved  Reserved  Reserved  Reserved  Reserved  Reserved  Reserved  2  3  4  5  6  7  8  9  10  11  12  13  14  15  16
4. We can also get the below information as well:
  • VPC Components for ECUTS Receiver Mass Interconnect Maintenance,
  • VPC Tools for ECUTS Receiver Mass Interconnect Maintenance,
  • Suggested VPC Components for ECUTS ITA Mass Interconnect Design and Maintenance,
  • Suggested VPC Tools for ECUTS ITA Mass Interconnect Assembly and Maintenance

Additional Information

You can take the link as example.