NI SystemLink DataFinder Error Could Not Connect With the Server: Bad Request: EXCEPTION

Updated Dec 18, 2025

Reported In

Software

  • SystemLink Server

Issue Details

I log in to the Database on the NI SystemLink Server and add indexes but when I try to access them from "Data Navigation", I receive the following error:

 

Error:

Could not connect with the server:<<DataFinderInstance>>

Bad Request: EXCEPTION: AoException: AO_UNKNOWN_ERROR (0): RequestorBase(92): ERROR(60): Error: cannot connect to server.

 

Data Navigation Error.JPG

 

How to resolve this error?

Solution

The problem occurs when the NI Services not running correctly in the Windows Services application of the PC. 

 

  • Ensure that the "NI PSP Service Locator"  is running correctly under Windows Services. 

 

PSP_start.jfif

 

  • If there are any errors while starting NI PSP Service Locator, please refer to the troubleshooting steps linked here.