This content is not available in your preferred language.

The content is shown in another available language. Your browser may include features that can help translate the text.

LabVIEW: (Hex 0x6C0) When Deploying Source Distribution to RT Target

Updated Apr 28, 2024

Reported In

Hardware

  • cRIO-9038
  • cRIO-9049
  • CompactRIO Controller

Software

  • LabVIEW

Issue Details

After built and deploying the RT Source Distribution to cRIO-9038 RT Target, deployment status shows failed to deploy. The error message is " LabVIEW: (Hex 0x6C0) A package has already installed the application you are trying to deploy. To resolve this error, uninstall the package before deploying the application."
LabVIEW Error Message

Solution

This error can occur due to a conflict between the VI's in vi.lib and the packages that are already installed in the RT target. To resolve this, make sure that these 3 options in "Additional Exclusions" of Source Distribution Properties is checked.
Build Specifications Additional Exclusion