Not Able to Insert Image in TestStand HTML Report

Updated Apr 18, 2024

Reported In

Software

  • TestStand 2020
  • TestStand 2021

Issue Details

I am able to insert image in HTML report for TestStand 2019 by following the steps in this link, but was not able to get the similar result using TestStand 2020 and TestStand 2021. It show the result in the image below :
 
2021-11-15_16h52_18.png

Solution

This behavior is due to a TestStand bug for version 2020 and 2021. The workaround is to select a Report Generator for Producing the Report Body using Sequence instead of DLL for HTML report.
 
2021-11-15_16h58_27.png