How to get EMVCo L1 Mobile Performance Test Specification

Updated Mar 26, 2020

Reported In

Hardware

  • Micropross Accessories

Other

S/W : MPManager3, EMVCo Mobile Performance Test Suite

Issue Details

  1. Could you please explain the objective of EMVCo L1 Mobile Performance test?
  2.  How to get the related Specification :
  • EMVCo Mobile L1 Performance Testing - Version 2.2 (December 2018)
  • EMVCo Contactless Specifications for Payment Systems – Book D – EMV Contactless Communication Protocol Specification, v2.6 (March 2016)

Solution

  1. EMV Mobile L1 performance :

The objective of Performance Testing is to ensure the mobile product performance is satisfying.
Most testcase are measurement of transaction time(processing time + transmission time) for each scenarios.
The result are average of 50 times measurements.

Mobile transaction time(Sum of Block time) = Mobile processing time(Sum of Block Processing Time) + Mobile transmission time((Sum of Block Transmission Time)

The result of each Tes case showing
o For mobile transaction time:
o For mobile processing time:
o For mobile transmission time:
o The transmission error rate
o The Total UICC processing time (when available for EE IDs: EE-UICC-A2 and EE-UICC-B2)
o For Mobile mobile Processing processing Time time – Total UICC Processing processing Time time (when UICC processing time is available for EE IDs: EE-UICC-A2 and EE-UICC-B2)

TESTCASE
There are several tescases for each EE ID configuration
1) EE ID = UICC : EE-UICC-A2 or EE-UICC-B2 --> 7 Test cases(Flow1~Flow7) for A2 , B2
2) EE ID = eSE or eUICC --> 6 Test cases(Flow C2~C7) for Type A,B
3) EE ID = HCE --> 4 Test cases(Flow C2~C5) for Type A, B

Each Flow has several C-APDU/R-APDU transaction (e.g. 9 or 6) and different size of Byte.

Note) User need above specific UICC and Test application for test.

 


2. How to get the Specification

  • EMVCo Mobile L1 Performance Testing - Version 2.2 (December 2018) :

Only allowed Laboratory and Tool provider, we cannot provide it.

  • EMVCo Contactless Specifications for Payment Systems – Book D – EMV Contactless Communication Protocol Specification, v2.6 (March 2016) :

You can find it from EMVCo website : link .