Why Is There No "NI Service Locator" Entry in My List of Services?

Updated Jan 3, 2020

Reported In

Other

  • NI Service Locator

Issue Details

I installed a version of LabVIEW that is newer than 2010, and I can no longer find the "NI Service Locator" in my Windows services listed in <Settings>»Control Panel»Administrative Tools»Services.
Additionally, the NI Service Locator executable cannot be found at C:\WINDOWS\system32\nisvcloc.exe.

Solution

Try to restart the service using the executable:

For LabVIEW 2010-2012, the NI Service Locator was integrated into the NI System Web Server. The executable is located at <Program Files>\National Instruments\Shared\NI WebServer\ If you recieve an error that mentions the NI Service Locator, any relevant troubleshooting steps should be performed with the System Web Server.

From LabVIEW 2013 onward, the NI System Web Server and NI Service Locator were split into separate components again. The executable of the NI Service Locator is located at <Program Files>\National Instruments\Shared\nisvcloc

Was this information helpful?

Yes

No