This content is not available in your preferred language.

The content is shown in another available language. Your browser may include features that can help translate the text.

Auto Detection of 3rd Party cRIO modules shows modules as unsupported

Updated May 21, 2025

Reported In

Software

  • LabVIEW FPGA Module

Driver

  • NI CompactRIO

Other

  • cRIO-904x
  • cRIO-905x

Issue Details

I want to use a 3rd module in my CompactRIO 904x or 905x. When I use the auto-detection, I get the following error:
 
mecfpoplloebipmo.png

When using a different cRIO controller, like a 9030, everything works.

Solution

On the new DAQmx-enabled CompactRIO controllers (904x and 905x), the auto-detection for 3rd party modules is not implemented.

To still use the modules, you can manually add the modules, like described in Adding a New C Series Module to a cRIO Project in LabVIEW.