I Have Pass With Warning Executing the CA144 Test of the EMVCo PICC Analog

Updated Dec 16, 2020

Reported In

Hardware

  • Micropross Accessories

Other

SW : EMVCo PICC Analog test suite version 3.0.5 (And later)

HW : CTSII

Issue Details

When I'm executing the test case CA 144, I have :
 
What is the problem ?

Solution

This test suite is checking DUT is compliant with the EMVCo Contacless Specification in an analog point of view. The Specification mentions that the transaction will considered as successful when the PICC answers all transaction sequences with each Response APDU containing a status word equal to 0x90 0x00. That's why you got a Pass to this test.