CAN Type of sbRIO Onboard CAN Port

Updated Jan 18, 2019

Reported In

Hardware

  • sbRIO-9607
  • sbRIO-9627
  • sbRIO-9637
  • sbRIO-9626
  • sbRIO-9633
  • sbRIO-9636
  • sbRIO-9606
  • sbRIO-9651
  • CompactRIO System on Module

Software

  • LabVIEW FPGA Module
  • LabVIEW Real-Time Module

Driver

  • NI-Embedded CAN for RIO

Issue Details

I am using sbRIO-9607. There is one onboard CAN port, but I don't know whether it is Low speed CAN or High speed CAN. What type of CAN I can use with sbRIO?

Solution

The sbRIO-9606/9607, sbRIO-9626/9627/9633/9636 and sbRIO-9651 System on Module (SOM) have onboard CAN and CAN transceiver.

According to sbRIO-9607 Specifications, sbRIO-9607 uses NXP PCA82C251T high-speed CAN transceiver that is fully compatible with the ISO 11898 standard and supports baud rates up to 1 Mbps.

Therefore, onboard CAN port of sbRIO uses high-speed CAN.