This content is not available in your preferred language.

The content is shown in another available language. Your browser may include features that can help translate the text.

CAN Type of sbRIO Onboard CAN Port

Updated Jan 18, 2019

Reported In

Hardware

  • sbRIO-9607
  • sbRIO-9627
  • sbRIO-9637
  • sbRIO-9626
  • sbRIO-9633
  • sbRIO-9636
  • sbRIO-9606
  • sbRIO-9651
  • CompactRIO System on Module

Software

  • LabVIEW FPGA Module
  • LabVIEW Real-Time Module

Driver

  • NI-Embedded CAN for RIO

Issue Details

I am using sbRIO-9607. There is one onboard CAN port, but I don't know whether it is Low speed CAN or High speed CAN. What type of CAN I can use with sbRIO?

Solution

The sbRIO-9606/9607, sbRIO-9626/9627/9633/9636 and sbRIO-9651 System on Module (SOM) have onboard CAN and CAN transceiver.

According to sbRIO-9607 Specifications, sbRIO-9607 uses NXP PCA82C251T high-speed CAN transceiver that is fully compatible with the ISO 11898 standard and supports baud rates up to 1 Mbps.

Therefore, onboard CAN port of sbRIO uses high-speed CAN.

WAS THIS ARTICLE HELPFUL?

Not Helpful