Error -1074097125 Occurs When Using Digital Pattern File in LabVIEW and DPE

Updated Dec 28, 2018

Reported In

Hardware

  • PXI Digital Pattern Instrument

Software

  • LabVIEW

Driver

  • NI-Digital Pattern Driver and Digital Pattern Editor 18.5

Issue Details

Running a representative LabVIEW example of Digital Pattern Instrument(DPI) result in Error -1074097125 as shown in the figure below when using specific Digital Pattern files.

 
Likewise, an error as shown below occurs when using a specific Digital Pattern file in the Digital Pattern Editor(DPE).

Why do these errors occur?

Solution

When you get this error in LabVIEW or DPE, you should try to check for any unnecessary characters in the path of the pattern file.

If there is non-English character such as korean, japanese, chinese on the path, the above errors occur.
Note : A file name can't also contain any of the following characters: \ / | : * ? " < >