Get Started with Astronics Ballard Card on Windows OS

Updated Nov 17, 2020

Reported In

Hardware

  • Ballard ARINC 429
  • Ballard MIL-STD-1553

Driver

  • Astronics Ballard Avionics Driver

Operating System

  • Windows

Issue Details

We have PXIe Astronics Ballard MIL-STD-1553, but we need to setup this hardware in a new PXI System.
What software do I need to install to program it in LabVIEW? Is there any getting started manual?

Solution

These steps show you how to set up Astronics Ballard cards on a Windows PXI system. If you have a Phar Lap ETS real-time PXI system, refer to Install Software for Astronics Ballard Cards on Phar lap ETS RT Target .
  1. Download the driver from the Astronics Ballard Avionics Driver download page. 
  2. Extract the files. There is a 32 and 64-bit installer. Run the installer that matches the operating system bitness.