Debugging Real-Time Sequences in VeriStand

Updated Sep 3, 2018

Reported In

Software

  • VeriStand

Issue Details

I am working with the  VeriStand Stimulus Profile Editor but I am seeing multiple errors while combining my stimulus profile with my  VeriStand deployment. Is there any tool to debug my Real-Time Sequence within the VeriStand Stimulus Profile Editor or  VeriStand?

Solution

The VeriStand Stimulus Profile Editor doesn't have built-in tools to debug your Real-Time sequences. Instead, you could do any of the following:
  • Implement data logging to monitor the data that you are interested, as an example you can refer to this example of implementing data logging on Real-Time Sequences.
  • Use the  VeriStand User Channels to map the data from your RT Sequence to the Workspace indicators, this way you could see how the data is behaving while it executes.
  • Use the  VeriStand SystemChannels to control/ monitor the execution of the Real-Time sequences
  • Use the Console Out to monitor the status of the execution on the RT target monitor.