What Do The Two Values On The Input Current Rating For A PXI Chassis Mean?

Updated Jun 14, 2018

Reported In

Hardware

  • PXI Chassis
  • Power Supply

Issue Details

  • When looking at the specifications for my PXI chassis device, the input current rating lists two values. What do these refer to?

Solution

These are the input current requirements for an American and European power supply respectively.

Additional Information

As the voltage output for an American and European power supply are 110 and 220 V respectively the input current when using an American power supply will be double that of the equivalent European power supply.

These values do not refer to the minimum and maximum current specifications.