Returned Results do not Match Query in LabVIEW

Updated Mar 6, 2018

Reported In

Software

  • LabVIEW Database Connectivity Toolkit
  • LabVIEW
  • LabVIEW Professional
  • LabVIEW Full
  • LabVIEW Base

Issue Details

I am using the Database Connectivity Toolkit, and when I provide a query, the returned result does not match the query provided. Why is this happening?

Solution

Try removing any inline comments. When the queries get passed to the server, it comes in as one line, and the inline comments may comment out the rest of the code, causing the returned result to not match the query provided.

WAS THIS ARTICLE HELPFUL?

Not Helpful