Cannot Upgrade RAM Past 4GB on PXIe Controller

Updated May 7, 2018

Reported In

Hardware

  • PXIe-8135
  • Upgrade/Spare RAM for PXIe-8135
  • PXI-8119
  • PXI-8119 Memory
  • PXIe-8840
  • PXIe-8840 Memory

Issue Details

On My PXIe controller, I can not upgrade the RAM past 4GB. I have tried all of the troubleshooting steps in the user guide. I have also tried upgrading the RAM on another PXIe-8135 and are getting the same results. If I try to put in two RAM sticks in or go from 4GB to 8GB with one RAM stick the system will not boot. 

I have put in a third party RAM stick into my PXIe controller, but my controller stills up in NI-MAX as only having 4 GB of RAM

Solution

On the user manual of the PXIe controller, there is a note reminding customers that third party RAM sticks are not guaranteed to work:
National Instruments sells RAM sticks specific to our controllers that are tested and guaranteed to work. Otherwise, we cannot guarantee the functionality of the device with RAM from third party companies. 

Additional Information

National Instruments offers the following SO-DIMMs for use with the PXIe-8840 controller:
  • 1600 MHz DDR3L PC3-12800 4 GB, 512 MB × 64, 1.18 in. max (NI part number 782341-4096)
  • 1600 MHz DDR3L PC3-12800 8 GB, 1024 MB × 64, 1.18 in. max (NI part number 783001-8192)