This content is not available in your preferred language.

The content is shown in another available language. Your browser may include features that can help translate the text.

NI System Web Server is Unregistered After Repair

Updated May 3, 2018

Reported In

Software

  • LabVIEW 2011 Professional
  • LabVIEW 2011 FPGA Module
  • SignalExpress 2011
  • LabVIEW 2011 Real-Time Module
  • LabVIEW 2013 Professional

Driver

  • NI-DAQmx 9.3.5
  • NI-VISA 5.1
  • NI-RIO 4.0

Other

NI System Web Server

Issue Details


I have repaired an installation of National Instruments software that includes the NI System Web Server. Now that software is no longer functioning correctly. How do I fix this problem?

Solution

This problem can be resolved by running a second repair on the same distribution.  In general, if you repair the installation of any of these distributions for any reason, you should complete this process a second time to ensure the NI System Web Server is registered. Be sure to restart your computer between repairs if prompted and ensure no background programs are using the LabVIEW Run-Time engine. 

This issue affects the following application software, application software modules, add-on software, and driver software.

Application Software
  • NI LabVIEW 2011 English 32-bit
  • NI LabVIEW 2011 English 64-bit
  • NI LabVIEW 2011 French
  • NI LabVIEW 2011 German
  • NI LabVIEW 2011 Japanese
  • NI LabVIEW 2011 Korean
  • NI LabVIEW 2011 Chinese
  • NI LabVIEW 2011 Runtime Engine 2011 32-bit
  • NI LabVIEW 2011 Runtime Engine 2011 64-bit
  • SignalExpress 2011
  • Measurement Studio 2010 SP1 VS2005
  • Measurement Studio 2010 SP1 VS2008
  • Measurement Studio 2010 SP1 VS2010
  • LabWindows/CVI 2010 SP1
  • Lookout 6.6

Application Software Modules

  • LabVIEW 2011 Real-Time Module
  • LabVIEW 2011 Real-Time Module (Japanese)
  • LabVIEW 2011 Real-Time Module (Chinese)
  • Real-Time Hypervisor 2.1 for Windows
  • LabVIEW 2011 FPGA Module Xilinx 10.1
  • LabVIEW 2011 FPGA Module Xilinx 12.4
  • LabVIEW 2011 DSC Module
  • LabVIEW 2011 DSC Module Runtime System
  • Vision Development Module 2011
  • LabVIEW 2011 Robotics Module
  • LabVIEW 2011 ARM Module
  • LabVIEW 2011 C Generator
Add-on Software
  • LabVIEW 2011 Desktop Execution Trace Toolkit
  • Vision Acquisition Software 2011
  • NI Vision Builder for Automated Inspection 2011
  • Motion Assistant 2.7
  • LabVIEW FPGA Compile Farm 2011
  • NI-RIO FPGA C API 2.0
  • 2011 ARM Compile Farm Toolkit - Client and Worker
  • Sound and Vibration Measurement Suite 2011
  • System Configuration 5.0
Driver Software
  • August 2011 NI Device Driver DVV
  • NI-DAQmx 9.3.5
  • NI-VISA 5.1 (Full)
  • NI-VISA 5.1 (Runtime)
  • NI-RIO 4.0.0
  • NI-Sync 3.3
  • FieldPoint 6.0.9
  • NI-Serial for Windows 3.8
  • NI Motion 8.3
  • NI-XNET 1.3.1
  • NI-SWITCH 4.3.5
  • NI-TimeSync 1.1.1
  • NI-ELVISmx 4.3
  • NI-845x 1.1.5
  • NI-Industrial Communication for DeviceNet 2.0.2
  • NI-Industrial Communication for CANopen 1.0.1

Additional Information

In LabVIEW 2013, there was a known issue where repairing LabVIEW would uninstall the Service Locator Dependency. However, this was fixed in the f1 patch as shown in LabVIEW 2013 Patch Details.

WAS THIS ARTICLE HELPFUL?

Not Helpful