Dieser Inhalt liegt nicht in Ihrer bevorzugten Sprache vor.

Der Inhalt wird Ihnen in einer anderen verfügbaren Sprache angezeigt. Ihr Browser bietet ggf. Funktionen, die Sie bei der Übersetzung des Textes unterstützen.

Control/Indicator, Local Variable, and Value Property Node Differences

Updated Oct 17, 2023

Reported In

Software

  • LabVIEW Base
  • LabVIEW Full
  • LabVIEW Professional

Issue Details

My VI runs differently when I use local variables as opposed to value property nodes or controls/indicators directly. What differences are there between these?

Solution

There are several performance trade-offs to consider when selecting which method to use for updating your front panel controls.  The available update methods are Controls/Indicators, Local Variables, or Value Property Nodes. Here are the benefits and negatives of each method:

Controls/Indicators
Benefits
  • Built in logic to prevent front panel updates when continuously updating the same value. This prevents front panel re-draws.
  • Do not need to de-reference pointers, nor make copies of the data in memory.  As such this is the fastest, and least memory intensive option.
Negatives
  • You cannot write to a single item in a cluster/array, but must update the entire variable
C analogy 
(this is not a C equivalent, but helps to show the steps that must be taken to update a corresponding front panel control/indicator).

int x;   // Front Panel Indicators
x = 10;  // Write directly to the Front Panel Indicator.



Local Variables
Benefits
  • Have built in logic to prevent front panel updates when continuously updating the same value.  This prevents front panel re-draws.
  • Do not need to de-reference pointers, unlike property nodes.  As such they are faster than property nodes.
Negatives
  • Memory intensive process.  These have the same front panel update logic as controls/indicators, however they must make a full copy of the data in memory for each local variable you create.
  • You cannot write to a single item in a cluster/array, but must update the entire variable.
  • Race conditions may occur if you are writing to and reading from the same local variable at different rates.
C analogy 
(this is not a C equivalent, but helps to show the steps that must be taken to update a corresponding front panel control/indicator).

int x; // Front Panel Indicator
int y; // Local variable
y=10;  // Write to local variable
x=y;   // LabVIEW does this for you to update the front panel.



Property Nodes
Benefits
  • Do not create copies of data in memory unlike Local Variables.
  • If you are using a non-strict control reference, then the data type of the value may be a variant rather than the actual data type of the control.
  • Capable of reading and writing of a single control within a cluster
  • Can be used to update front panel controls from within a SubVI
Negatives
  • Required to update the front panel item every single time they are called.  
  • They are a pass by reference function as opposed to a pass by value function.  This means they are essentially pointers to specific memory locations.  The pointers must be de-referenced, and then the value in memory updated.  The process of de-referencing the variables causes them to be slower than Controls/Indicators, or Local Variables.
  • Property Nodes cause the front panel of a SubVI to remain in memory, which increases memory use.  If the front panel of a SubVI is not displayed, remove property nodes to decrease memory use.
C analogy 
(this is not a C equivalent, but helps to show the steps that must be taken to update a corresponding front panel control/indicator).

int x;                  // Front Panel Indicator
int *x_pointer = &x;    // Create pointer to Front Panel Indicator 
                        // (Property Node)

*x_pointer = 1;  // * is used to dereference the pointer and update
                 // variable X. This is the operation that happens
                 // every time a property node executes.
Products may include a surcharge. Surcharge is calculated during checkout for U.S. customers. Learn more

Was this information helpful?

Yes

No