Error -107436013 Coming out of IMAQdx Open Camera.VI

Updated Jun 6, 2019

Reported In

Hardware

  • PCIe-8237

Software

  • LabVIEW
  • Vision Assistant
  • Measurement & Automation Explorer (MAX)

Driver

  • NI-IMAQdx

Issue Details

I'm getting Error 10743601310 saying the VISA Resource is already in use, with the error coming out of one of my IMAQdx VI's. The GIGE camera I'm using works in NI MAX, and Vision Assistant, but not in LabVIEW.

Solution

This error is caused by two applications trying use the camera at the same time. Ensure that all other programs on your computer aren't using the camera, or are closed down. Secondly, if your computer is connected to a network or internet, it's possible that another computer on the network is able to access your camera. Try disconnecting your computer from the network to see if this resolves the issue.