Hang Error On Remote Front Panel

Updated May 25, 2018

Reported In

Software

  • LabVIEW
  • LabVIEW Real-Time Module

Operating System

  • NI Linux Real-Time
  • PharLap

Issue Details

I am trying to use a remote front panel to interact with an executable hosted on my real time controller. However, when I direct my browser to the html file on my real time controller the remote front panel just hangs with the following message:
Downloading Panel 0.00% of 0 bytes

Solution

There are two solutions to this problem depending on the underlying cause:
  1. Your firewall or anti-virus is blocking communication between your host system and the real time controller. In this case ensure your systems can properly communicate with each other by setting the appropriate exceptions to your firewall and anti-virus.
  2. You are missing the necessary software to properly set up the remote front panel. Ensure you have installed all the necessary software as detailed in: National Instruments Product Compatibility for Microsoft Windows 10