How to Execute Each Model in VeriStand on a Separate Core?

Updated May 25, 2018

Reported In

Hardware

  • PXI Controller

Software

  • VeriStand

Operating System

  • VxWorks
  • NI Linux Real-Time
  • PharLap

Issue Details

I have a several complex models imported in VeriStand project, how can I execute each model on a seperate core in order to get a maximum performance from my Real-Time system?

Solution

In order to define on which core of a CPU your mathematical model will be executed do the following:
  1. Open System Explorer by double click on your System Definition File
  2. Go to Target >> Controller >> Simulation Models >> Models
  3. Select your model from Models list
  4. Set Simulation Model processor to Manual
  5. Set core on which this model will be executed
  6. Repeat steps 3 - 5 for each model

WAS THIS ARTICLE HELPFUL?