Additional Information
The LED behavior for the M Series and X Series DAQ devices is listed below for reference.
X Series USB DAQ Device:
| ACTIVE LED | READY LED | USB DEVICE STATE |
|---|
| Off | Off |
| | The device is not powered or not connected to the host computer or the host computer does not have the correct version of DAQmx installed. |
|
| Off | On | The device is configured, but there is no activity over the bus. |
| On | On | The device is configured and there is activity over the bus. |
| Blinking | On | The device is configured and there is activity over the bus. |
M Series USB DAQ Device:
| Power(+5V) LED | Active LED | Ready LED | USB Device State |
|---|
| Off | Off | Off | The device is not powered on. |
| On | Off | Off | The device is not powered or not connected to the host computer |
| On | Off | On | The device is configured, but there is no activity over the bus. |
| On | On | On | The device is configured and there is activity over the bus. |
| On | Blinking | On | The device is configured and there is activity over the bus. |
When using Virtual Machines
As detailed in the
Are NI Products Supported on Virtual Machines (VMs)? article, NI does not support NI hardware in virtual machines. If you'd like to troubleshoot without NI's assistance you can verify your VM USB settings.